(1) Empirically constructed brick curtain-walls shall-
a)have a thickness which is –
i) not less than 215 millimetres; and
ii) uniform throughout the height of the wall in any one storey; and
b)nor exceed a height of-
i) 5,4 metres in any one storey; or
ii) a total of 18, 3 metres when laid in class A, B or C mortar; or
iii) a total of 7,2 metres when laid in class D mortar
(2) Empirically constructed solid brick or cavity brick panel-walls have an effective thickness of not less than 100 millimetres.
(3) The effective thickness of faced panel-walls shall include brickwork and facing, but that of veneered panel-walls shall exclude the veneer.
(4) walls constructed as panel-walls shall sustain no forces other than their own mass and wind forces unless such other forces are approved by the local authority.
(5) Panel-walls which contain openings shall be fixed along their tops in the manner specified in section 31, and the curves designated in Figure 1 as “top fixed” refer to panel-walls so fixed.
(6) The length and height of any panel-wall shall not exceed the values corresponding to any point on the appropriate curve in Figure 1 for the relevant condition of the top of the panel-wall and its thickness.