Content Page: 9 Drainage and Sewerage

  • Vents: General

    (1) Every soil-pipe, waste-sewer and sewer, including every branch thereof which exceeds six metres in length, measured from its junction with a ventilated private sewer or a ventilated soil-pipe to its point of connexion with the soil-fitting which it serves, shall be provided with a ventilation-pipe leading up-wards from its highest convenient point. (2) Every…

  • Minimum Size Of Pipes, Etc

    Subject to the provisions of sections 36 and 37, no soil type, private sewer or waste-sewer shall be less than 100 millimetres in diameter: Provided that a waste-sewer not exceeding 4,6 metres in length or a soil-type serving urinals or bidets may be less than 100 millimetres but not less than 50 millimetres in diameter.

  • Capacities Of Vertical Pipes

    Every vertical pipe shall be of such a diameter that- a) the rate at which sewerage flows through such pipe at any point does nnot exceed the rate shown for the pipe of that diameter in column 2 or column 3 of Table VI, whichever is applicable; and b) the rate at which sewage enter…

  • Capacities Of Horizontal Pipes

    Every horizontal pipe or sewer having a diameter set out in column 1 of Table V shall be deemed to have a maximum discharge capacity set out in column 2 for such pipe and set out in columns 3,4,5 and 6 for such sewer, and the aggregate rate of discharge of all sanitary fittings discharging…

  • Distinction Between Horizontal And Vertical Pipes

    For the purpose of the provisions of this Chapter, any pipe which is inclined to the horizontal at an angle of less than 45 degrees shall be deemed to be a horizontal pipe, and any other pipe shall be deemed to be a vertical pipe.

  • Rates Of Discharge From Sanitary Fittings

    Any sanitary fitting with an outlet of a diameter referred to in column 1 of Table IV shall be deemed to discharge sewage at the rate stated for such sanitary fitting in column 2 or column 3 of such table, which ever is applicable. TABLE IVTABLE V

  • Discharge Units

    (1) For the purposes of this section, the rate at which sewage is discharged into, or at which it flows through, a pipe or sewer shall be measured in units which are herein referred to as “discharge units” (abbreviated reference d.u) (2) The rate at which sewage flows through a pipe or sewage flows through…

  • Solder

    Solder used for plumbing shall comply with the requirements of C.A.S. No H3, Soft solders

  • Asphaltic Compound

    Asphaltic compound used for joints shall not- a) be brittle at normal temperature; nor b) soften sufficiently to destroy the effectiveness of the joint when subjected to a temperature of 70°C; nor c) be soluble in any of the wastes carried by the sewerage system.

  • Jointing

    Jointing of sewers and fittings shall be made- a) with materials approved for use with the particular material of which the sewers and fittings are made; and b) in such a manner as- (i) to prevent leakage from the joint; and (ii) where necessary, to allow some moment of the joint.